Sök:

Sökresultat:

1479 Uppsatser om Passive house standards - Sida 1 av 99

Passivhus ? lönsamhet och komfort

In this essay, we have compared a conventional house to a passive house. The housesshared the same local conditions; they have the same living area and the same layout. Thedifferences between the houses were the different construction solutions for the roof, theouter walls, the floor and the heating system. Both the houses qualify the standards fromBBR and the passive house also lives up to FEBY?s special conditions.The purpose with the essay was to examine if it really is profitable to build small hoses aspassive houses.

Passivhuset i det långa loppet : - hur påverkar brukarens kunskap energiförbrukningen?

The scope of this investigation is to decide how and to what extent the energy consumption of apassive house is affected by the users? knowledge and habits. To achieve this a literary study hasbeen made and as a complement the planning of a passive house was completed.The result of a primary study of the rules and regulations that effect passive houses in Swedenshows that the user?s influence on passive houses is a completely unregulated area. Even thoughthere is no regulation, a need for some general knowledge of the passive house concept has beenexpressed.To further investigate how the users? knowledge and habits affect the energy consumption and ifthere is a difference between different households? energy consumption , three main factors havebeen identified.

Erfarenheter från flerbostadshus som passivhus : En handflata och sex värmeljus

All new households were to be constructed with "near zero energy house standards" (NZE-house) by the year of 2020. The ambition to construct energy-efficient buildings had to increase rapidly in the spring of 2013.The purpose of this report was to increase the interest for building contractors to construct apartment buildings with Passive house standards. By locating and evaluating experiences from an existing passive house a case study including interviews, field visits and document analysis was made. Research of literature regarding other passive houses in Sweden also helped to answer the following questions:- What positive and negative experiences have the study of the passive house meant to the involved stakeholders and residents?- What improvements can be made based on identified experiences?- How can an apartment building be designed as a passive house based on possible improvements?By collecting good and bad experiences, as well as improvements and potential design proposals, a diagram was created designed as a tool for developers when constructing apartment buildings with Passive house standards.

Passivhus vid polcirkeln : Fungerar det?

This report is the product of the course AF101X, a bachelors degree in Samhällsbyggnad atKTH. The task of the course is to design a small house at a given location and also implement adeepening study. The house in this report is located in Kiruna in the north of Sweden, where theclimate is much colder than in the rest of the country.The deepening study of this report is to evaluates how realistic passive housing north of thePolar Circle is based on those facts. The house will to some extent be designed to fit the passivehousing standard.

Projektering av ett småhus med fördjupning i uppvärmningssystem

This report aims to examine the design of a passive house. The design addresses the selection ofmaterial, sizing and selection of both building services systems and building technical features suchas load-bearing framework and moisture control. Interior layout is designed for a family of twoadults and one child.A big part of the report is devoted to an in-depth comparison of three different wall constructions ofpassive house standard. The structures that have been compared are a lightweight timber structure, aheavier concrete structure and a sandwich wall of the brand Weber Leca. The report covers variousaspects such as air flow, wall thickness, the risks associated with the construction, U-value, thermalbridges, power consumption, price, and assembly costs.

Passivhus : En jämförelse mellan olika byggnadstekniska lösningar för ytterväggar

This report aims to examine the design of a passive house. The design addresses the selection ofmaterial, sizing and selection of both building services systems and building technical features suchas load-bearing framework and moisture control. Interior layout is designed for a family of twoadults and one child.A big part of the report is devoted to an in-depth comparison of three different wall constructions ofpassive house standard. The structures that have been compared are a lightweight timber structure, aheavier concrete structure and a sandwich wall of the brand Weber Leca. The report covers variousaspects such as air flow, wall thickness, the risks associated with the construction, U-value, thermalbridges, power consumption, price, and assembly costs.

Stomme i småhus ! : - En teoretisk studie av olika bärande vägglösningar !

This report aims to examine the design of a passive house. The design addresses the selection ofmaterial, sizing and selection of both building services systems and building technical features suchas load-bearing framework and moisture control. Interior layout is designed for a family of twoadults and one child.A big part of the report is devoted to an in-depth comparison of three different wall constructions ofpassive house standard. The structures that have been compared are a lightweight timber structure, aheavier concrete structure and a sandwich wall of the brand Weber Leca. The report covers variousaspects such as air flow, wall thickness, the risks associated with the construction, U-value, thermalbridges, power consumption, price, and assembly costs.

Förskolor med passivhusteknik : En utredning av passiva förskolor

As a result of directives from EU, with the ambition to reach environmetal goals, The German organisation Passivhaus Institut has defined a passive house. A passive house is a building that is very energy efficient and makes a small impact on the environment. The energy from the inhabitants as well as the appliances & fixtures in the building should equal the energy that is required to heat the building. A Swedish version of the passive house definition has been defined, taking into account the climate conditions and the difference in building regulations.This thesis is a request from Skanska on how it can improve and develop an ongoing passive house project, involving an infant school. The intention of this thesis is to identify difficulties & display potential development areas for infant schools.The method of research conducted is as follows: interviews of clients, ventilation consultant, consultant for heating system and an energy calculation consultant, an inspection of the infant shcool in process, investigation of completed infant schools and a study of relevant literature.From this research it was found that it is difficult for infant schools to pass the criteria for passive houses. The conclusion of this thesis provide several guidelines on how to improve the outcome of existing projects & the steps needed to be taken for future development in this area..

Passivhus av helväggselement i träull

Environmental destruction is a growing problem in our world. Almost every day there are new reports concerning that we have to do something about the greenhouse gasses. Simultaneously is the human constantly more eager to have a life with higher standards and therefore uses more energy. The environment is a question that is highly up-to-date and more people try to find solutions on how to save our planet. One way to decrease the energy demand is to build passive houses, where the houses don?t have any active heating.

Redesign of an existing apartment block in Kv Preussen to passive house

Passive houses are a relatively new concept in Sweden and by that it is meant a house without a traditional heating system. The most acknowledged passive house project is the terrace houses in Lindås, Gothenburg, which we have used as a reference. This project concerns a square apartment block. So far, no square apartment block has been built as a passive house in Sweden.The common opinion in the construction industry is that it is not economical to build extremely energy efficient houses. With Peab as commissioner our task was to investigate if that is true, if regarding the construction of a multi storey house as a passive houseMidroc, now owned by Peab, constructed in the block of Preussen in Jönköping during 2004-2005 four houses, with 132 apartments distributed on seven floors.

Det självförsörjande passivhuset

The housing sector uses 40 % of the energy in Sweden and half of the electricity usage. Theuse of energy is the main reason to the increasing rate of carbon dioxide in the atmosphere.This is the main motive but also a wish of higher safety, that is a higher rate of selfsufficientenergy production in Sweden, we want to decrease the need of using fossil fuel. Now whenthe energy price rise, the interest in energy issues increase and more people discuss thepossibility of reducing the usage of fossil fuel. A change to renewable energy such as sun,wind and water is the only solution where we can get a sustainable development.One way to contribute to a better use of energy is to build in the principle of passive house.The house is being built with a thick and tight insulation. If you use a heat-exchanger withhigh degree of efficiency and a final heating battery on the ventilation system, the heat fromlamps, devices and the ones living in the house should be enough to fulfil the criteria ofliving.

Prefabricerade Passivhus

European Union has made a new decision that all new built houses by 2020 shallbe near-zero energy houses. Boverket?s definition of near-zero energy housesintends buildings with good energy performance in which a proportion of theamount of energy that must be added to the building is made of renewable energy.Passive House is a set of requirements from FEBY designed to build energyefficient buildings. This is achieved by reducing loss of heat through the buildingenvelope and to take advantage of the passive heat from solar radiation,installation and heat sources like people living in the house.This project has been made with help of Anebyhus and one of their model houseshave been examined from the report?s issues, including Anebyhus?s energyperformance, requirements for the manufacturing and assembly, how theenvelope must be improved to fulfill the requirements for the Passive House andwhat energy calculation programs are available on the market.The report aims to provide solutions for energy efficient houses that are adaptedfor production of house building.Two visits to Anebyhus has been done to study their manufacture and assemblyof building elements.

Utvärdering av befintliga passivhus : En byggnadsfysikalisk bedömning och mätningar om temperatur, och fukt analys på ytterväggarna

Energy price are on the way up to a high level that will not diminish in the future make us to focus more on the sustainable development for a better solution of residential houses. Passive house or low energy housing are one of the solution to make residential more environment friendly, in same time it´s a financial security using less energy, and saving money. The last 10 years in Germany and all around Europe the concept of passive house been developed, and people aim to know more about these concept that leading the market more attractive for passive houses. A passive house is a well designed building highly insulated and air tight with mechanical ventilated system for the whole building envelope that minimizes the use of energy for heating [1].The housing company Mimer has chosen to invest in low energy consumption in every new housing project.  These future plan projects are decided to use less than 75 kwh per square meter annually in purchased energy [2].This thesis is about new constructed passive houses, and focuses on the evaluations of the temperature, and moisture condition for attic, external walls and joist.

Primärenergianvändning av passivhus i Sverige : Med fokus på Kvarteret Trettondagen

The building sector accounted for around a fourth of the total energy usage in Sweden in year 2010 (Energimyndigheten, 2012). Therefore it has become very interesting to achieve a lower energy usage in residential buildings. One way to achieve that is to build so called passive houses. By being very well insulated and have low leakage through the walls, they can reduce the energy usage for heating with a substantial amount. The first passive house was built during the 90?s in Germany; and in Sweden the first passive house was built in Gothenburg 2001.

Nollenergihus i Borlänge : Är det möjligt med biomassa, solenergi och vindkraft?

This report is of technical character and treats how to plan a small building in Borlänge, Sweden.The technical components that have been treated in the report are the construction, foundation,installations and thermic abilities of the house. In addition to planning this house the report alsocontains a part that deepens in net zero energy buildings. The purpose of the report is toinvestigate if the house in Borlänge can be constructed to meet net zero energy buildingdemands.Energy efficient houses such as passive- and net zero energy houses are showing more frequenton the market in Sweden. Ongoing climate changes and growing consciousness about theenvironment in society have contributed to that the environment is a well discussed topic. Toconsume small amounts of energy and at the same time produce local energy is thereforesomething that lies in the future and future houses.

1 Nästa sida ->